A9130 BSC紧急情况的处理方法
wangminghao
入门会员
鎵嬫満鍙风爜宸查獙璇


 发短消息    关注Ta 

积分 30
帖子 6
威望 461 个
礼品券 0 个
专家指数 0
注册 2008-3-3
专业方向 
回答问题数 0
回答被采纳数 0
回答采纳率 0%
 
发表于 2012-06-24 13:49:05  只看楼主 
【资料名称】:A9130 BSC紧急情况的处理方法

【资料作者】:ASB

【资料日期】:2012

【资料语言】:中文

【资料格式】:DOC

【资料目录和简介】:

A9130 BSC紧急情况的处理方法

第一部分:状态检查
1,SBL 状态检查
通过OMC,或者BSC Terminal检查
1.1观察各个硬件模块的状态灯,初步判断故障模块。
1.2通过OMC终端,可以直接检查当前告警和历史告警,通过图形界面直接查看各个SBL的状态。
1.3通过BSC Terminal可以使用commands-》Equipment handling-》SBL status List查看各个SBL状态。
1.4 Mx BSC主要有以下的告警种类,具体的操作可以参考alarm dictionary。
告警的种类列表:
29 Class 97: ATCA-PROCESSOR Alarms
29.1 [97,0] RESET
29.2 [97,1] TAKEOVER
29.3 [97,2] RLC-OV
29.4 [97,3] ACCESS-FAIL
29.5 [97,4] APPLICATION-FATAL-TERMINATION
29.6 [97,5] SYSTEM-FATAL-TERMINATION
29.7 [97,6] UNPLUGGED
29.8 [97,8] FW-UPGRADE
29.9 [97,10] FATAL-HW-FAILURE
29.10 [97,11] TEMPERATURE-CRITICAL
29.11 [97,12] TEMPERATURE-MAJOR
29.12 [97,13] TEMPERATURE-MINOR
29.13 [97,14] VOLTAGE-FATAL
29.14 [97,15] VOLTAGE-MAJOR
29.15 [97,16] VOLTAGE-MINOR
29.16 [97,17] ETHERNET-LINK-FAILURE
29.17 [97,20] CONFIGURATION-FAILURE
29.18 [97,21] TAKEOVER-REFUSED
29.19 [97,30] N7-DEVICE
29.20 [97,31] HDLC-HANDLER
29.21 [97,32] Q1-HANDLER
29.22 [97,33] RW-HANDLER
29.23 [97,34] TDM-FAILURE
29.24 [97,35] E1-FRAMER
29.25 [97,36] TP-MAIN-SW-ERROR
29.26 [97,37] TP-MAIN-FILE-ERROR
29.27 [97,38] TP-MAIN-ACCESS-PB
29.28 [97,39] SS7-SW-ERROR
29.29 [97,50] NE1OE-FAILURE
29.30 [97,51] E1-SL-FAILURE
30 Class 98: ATCA-SWITCH Alarms
30.1 [98,0] RESET
30.2 [98,3] ACCESS-FAIL
30.3 [98,6] UNPLUGGED
30.4 [98,8] FW-UPGRADE
30.5 [98,10] FATAL-HW-FAILURE
30.6 [98,11] TEMPERATURE-CRITICAL
30.7 [98,12] TEMPERATURE-MAJOR
30.8 [98,13] TEMPERATURE-MINOR
30.9 [98,14] VOLTAGE-FATAL
30.10 [98,15] VOLTAGE-MAJOR
30.11 [98,16] VOLTAGE-MINOR
30.12 [98,18] IP-ROUTER-LINK-FAIL
31 Class 99: ATCA-SHELF Alarms
31.1 [99,0] RESET
31.2 [99,3] ACCESS-FAIL
31.3 [99,6] UNPLUGGED
31.4 [99,8] FW-UPGRADE
31.5 [99,10] FATAL-HW-FAILURE
31.6 [99,11] TEMPERATURE-CRITICAL
31.7 [99,12] TEMPERATURE-MAJOR
31.8 [99,13] TEMPERATURE-MINOR
31.9 [99,14] VOLTAGE-FATAL
31.10 [99,15] VOLTAGE-MAJOR
31.11 [99,16] VOLTAGE-MINOR
31.12 [99,17] ETHERNET-LINK-FAILURE
31.13 [99,18] SHELF-MANAGER-ACCESS-PB
31.14 [99,19] FAN-FAILURE
32 Class 100: LIU-SHELF Alarms
32.1 [100,0] RESET
32.2 [100,1] MUX-TAKEOVER
32.3 [100,4] ACCESS-FAIL
32.4 [100,6] UNPLUGGED
32.5 [100,8] FW-UPGRADE
32.6 [100,17] PEM-FAILURE
32.7 [100,18] 48V-REDUNDANCY-LOSS
32.8 [100,50] NE1OE-FAILURE
32.9 [100,51] E1-SL-FAILURE


2,进程状态的检查
通过script检查或者pstree的命令检查,下面是通过script检查的方法。
2.1通过BSC terminal查看当前HW mapping
Commands-》BSS Operations-》Display HW Log Mapping Type查看当前各个active的模块。
2.2.1连接active的OMCP,以root 、alcatel的用户名和密码登陆。
2.2.2 进入 usr/local/bin目录,运行./mx_chkSanity.
2.2.3检查var/log/MX/trace/files/AuditMxBSC.trace或者var/log/MX/logs/ AuditMxBSC.log,查看当前各个进程的状态。



第二部分:A9130 Trace和现场数据的收集
1,A9130 trace的收集。
紧急情理时请根据TAC和ISE总部的要求按照以下方法收集trace。
1.1 Introduction
In MXBSC, some trace are enable automatic, some other trace need manually to open them. The table show all the trace available for MXBSC
BoardTrace typeEnableComments
OMCP/CCP/TPcore dump fileAutomatic-VOS core, nonVOS core and selfRelient core files=/var/log/MX/trace/dump/files
--
OMCP/CCP/TPLinux system log,
Automatic-dmesg command to see the startup result
-all the log file located in /var/log/
OMCP/CCP/TPSelfRelient logAutomatic-selfRelient log file are stored in /var/log/MX/trace/srk/
OMCP/CCPNTP logAutomatic-/var/log/MX/logs/NTP
OMCP/CCPVCE realtime trace(SCPR,OCPR, TCU,DTC,TSC)Request from trace terminal-trace file will be finally stored in OMCP disk /var/log/MX/trace/realtime/files
OMCP/CCPVCE daily traceRequest from trace terminal-trace file will be finally be stored in OMCP disk: /var/log/MX/trace/daily/files
OMCPMxPF current logAutomatic-trace file will be finally be stored in OMCP disk: /var/log/MX/logs/
OMCP/CCPVCE Interactive traceRequest from trace terminal-trace file will be finally be send to trace facility terminal, use du
TP/OMCP/CCPNon-VCE trace(CMW,EIM,CPI, SWMGT,TPMAIN,SLH …)Manually active from each board-trace file will be finally be stored in OMCP disk: /var/log/MX/trace/files
1.2 Trace class and sub-class
For each trace active, we can define the class and subclass, these two parameters are used to filter the trace, display only the trace we interested.
For VCE realtime trace, the detail meaning of the class and subclass can be found in trace facility terminal menu. Trace-> Realtime trace-> Get/set configuration data. The information can also been found in Trace facility terminal user guides.
1.3 Default trace
When MXBSC is coming up, the default trace already been opened background. For each VCE, when there’s non-recoverable error happens, maximum 512K trace will be save to disk. The default VCE trace include the following class: ERROR,MSG,API,FST with priority 3 and dump lever 1.Default trace is only activated for the VCE on the OMCP board, not for the VCE on the CCP board.
1.4 Active VCE realtime trace
MXBSC uses a trace config file to control all the trace in all the VCEs. The following command can show the trace file name:
root@OMCP1-n3s30#ls /common/bsc/SCPRDISK/|grep BSC
BSCTRACE.01F
The following is the way to active VCE realtime trace:
Active trace from trace facility terminal, after connected to BSC, trace facility terminal support the following operation
a.Get/Set/disable the trace for one VCE.
b.Get/Set/disable trace for more than one VCE.
c.Forcelly dump trace to OMCP disk.
1.5 Active NonVOS trace
To open a non-VCE trace, we need to modify the config file in all the boards.
vi /usr/local/trace/conf_custom/trace_dyn_mxpf.conf
vi /usr/local/trace/conf_custom/trace_dyn_appli.conf
/usr/local/trace/bin/snd2ctm trigger 127.0.0.1 send the trigger to own board to active trace
/usr/local/trace/bin/snd2ctm get_shm 127.0.0.1 check the traces enabled successfully or not

1.6TP和CCP的realtime内容。
由于TP和CCP没有DISK,在reset后相关的内存里的trace将丢失。所以在reset前对于TP板需要登录到TP板上(110和130),在usr/local/tpgsm/tools下,运行./tp_debug 5,在把/var/log/MX/dump/common下的文件备份下来。对于CCP板也需要将/var/log/MXtrace/common下的内容备份,再对板子reset。

2,跟踪相关的A口信令,并保存记录。

3,保存bsc terminal log


4,备份问题解决前后的DLS

5,收集二进制历史告警
注意事项:对MX各个模块的操作命令,尽量BSC侧进行,不要通过OMCR执行。

第三部分:问题的简单处理
1,在保存好相关的trace后,根据前面的检查情况。可以对相关的TP,CCP和OMCP进行reset的尝试操作。
2,如果reset后仍然没有效果,可以尝试reset(或者开关电)A9130 BSC。
扫码关注5G通信官方公众号,免费领取以下5G精品资料
  • 1、回复“YD5GAI”免费领取《中国移动:5G网络AI应用典型场景技术解决方案白皮书
  • 2、回复“5G6G”免费领取《5G_6G毫米波测试技术白皮书-2022_03-21
  • 3、回复“YD6G”免费领取《中国移动:6G至简无线接入网白皮书
  • 4、回复“LTBPS”免费领取《《中国联通5G终端白皮书》
  • 5、回复“ZGDX”免费领取《中国电信5G NTN技术白皮书
  • 6、回复“TXSB”免费领取《通信设备安装工程施工工艺图解
  • 7、回复“YDSL”免费领取《中国移动算力并网白皮书
  • 8、回复“5GX3”免费领取《 R16 23501-g60 5G的系统架构1
  • 对本帖内容的看法? 我要点评


    作者的更多帖子
     
    [充值威望,立即自动到帐] [VIP贵宾权限+威望套餐] 另有大量优惠赠送活动,请光临充值中心
    充值拥有大量的威望和最高的下载权限,下载站内资料无忧
    sjzdxwl55555
    中级会员
    鎵嬫満鍙风爜宸查獙璇


     发短消息    关注Ta 

    积分 540
    帖子 108
    威望 1878 个
    礼品券 0 个
    专家指数 0
    注册 2011-6-19
    专业方向  网络优化
    回答问题数 0
    回答被采纳数 0
    回答采纳率 0%
     
    发表于 2012-06-24 17:16:33 
    技术问题,回答得专家指数,快速升级
    下载包呢?楼主?

    对本帖内容的看法? 我要点评

     
    [立即成为VIP会员,百万通信专业资料立即下载,支付宝、微信付款,简单、快速!]

    快速回复主题    
    标题
    内容
     上传资料请点左侧【添加附件】

    当前时区 GMT+8, 现在时间是 2026-05-05 04:02:57
    渝ICP备11001752号  Copyright @ 2006-2016 mscbsc.com  本站统一服务邮箱:mscbsc@163.com

    Processed in 0.355163 second(s), 13 queries , Gzip enabled
    TOP
    清除 Cookies - 联系我们 - 移动通信网 - 移动通信论坛 - 通信招聘网 - Archiver